Find Car Lifter, Cargo Elevator, Electric Hoist on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Passenger Elevator > Residential Stretcher Elevator-Kjx-DJ01

Residential Stretcher Elevator-Kjx-DJ01

Payment Type: L/C, T/T
Min. Order: 1

Basic Info

Model No.:  KJX-DJ01

Product Description

Model NO.: KJX-DJ01 Capacity: 500-1000kg Speed: 1.00 - 2.00m/s Machine Room: Optional Usage: for Passenger Warranty: 18 Months After Shipment Date Transport Package: Standard Wooden Export Packing Origin: Zhejiang, China Driving Type: AC Elevator Persons: 6 - 10 Model: Gearless Passenger Elevator Material: Hairline Stainless Steel System: Monarch 3000new or Step Trademark: KUIKO or OEM Specification: GB7588-2003 and EN81 HS Code: 8428101090
This passenger stretcher elevator has an exact and effective control system by using the most advanced technology. In additon to this, KUIKO elevator provide best price for our customers.

The goal of KUIKO elevator is best quality, good price, punctual shipment and superior service.

1. Elevator Production Description:

Ceiling: KDD-01
Control box: KCZ-01
Car wall: Hairine stainless steel
Front wall: Hairline stainless steel
Lintel: Hairline stainless steel
Sedan gate:  Hairline stainless steel
Floor: KDB-01( Material: PVC)
Arm Rest: KFS-01, one arm rest in back wall

2. Installation:

We are not responsible for the installation for overseas customers, but, we are happy to send our engineers to accomplish the installation at customers' costs if it is really needed. We are not recommend our esteemed customer to adopt in this way, as the cost is really huge indeed.

3. Agent Wanted:

We are always looking for qualified/experienced elevator distributors to cooperate with us on long term basis. We are happy to provide distributors our promotion price as reward for the cooperation. International agent business and/or OEM manufacturing, both are welcome to our company.

4. Aftersales Services:

We guarantee that all the spare parts and/or accessories were original quality products. We guarantee that all the production and inspection in our factory were strictly carried out according to Chinese Standard GB7588-2003 & Europe Standard EN-81.

 
Basic function
Collective Control In automatic or drive operation state, the elevator will automatic response the signal from instructions, operation direction etc, any passenger in each floor can call elevator.
Inspection travel This function is used in inspection or testing of elevator. When in line with the operating conditions, press up/down button, the lift willoperate upwards or downwards by the inspection speed. When it loosens the button, it will stop the operation.
     low speed self-correction operation When the elevator under un maintenance, and did not stop on a flat area. At this time if meet requirements for safety operation, the elevator will automatically slow running to a flat area, and open the door.
test running It is designed to test or examination new ladder function. The all-in-one a parameter is set to test running, the elevator will automatically run. the total number of Automatic operation and interval time of each run can be set by parameter.
Timing control System has internal real-time clock, so when breakdown, elevator will write down the exact time of each fault occurring; In addition, some function involving the time control based on clock.
door opening/closing adjusting Rise the system performance by adjusting the door hold time for both car door and landing door separately.
in-the-hall door opening In the halls, the doors can be opended by means of pressing the door-opening button. As long as the button is being pressed, the door will keep opening.
the close door button can be used to close the door in advance Under Automatic status, press the close button, it can cancel door opening function. When the door is in the open position, the close button can be used to close the door immediately.
          exchange landing If the time of the elevator openning more than set time, the door limit still no act, the elevator will turn into a closed state, and after the door closed, the elevator will drive to the nearest landing.
false order cancellation function This function refers to the cancellation of a falsely resigisterd order/calling; this can be done through continously pressing the button twice.
Direct arrival Elevator low spped according to the principle of distance, no operation at the flat layer.
load non stop When the car carrying weight to full load(normally 80%capacity), the full signal will generate in the hall display, the elevator will only response the car signals and no longer response hall signals.
energy saving with illumination and ventilation(time can be customized) Under automatic state, if elevator without instructions or outside call registered more than 3 minutes (3 minutes is the default value, this time can be adjusted through the parameter), the system will automatically cut off power of illumination and ventilation fan in the car. However, all these functions will be reemployed as soon as elevator receives the instructions or calls..
floor of lobby When automatic running, if floor of lobby function is valid, so when no resgistration of calls or operations after preset timeout, the car will return to preset main stop and wait there.
retry shutting down the door In order to prevent the door can not closed by the accidental failure of door operation system or certain obstacle blocked in the middle of the door. Under this situation, try to close again.
the operational fault records The record can contain up to 20 functioning incidents that happened most recently, including time ,floor, the code deployed for each incident.
self-tuning of landing distance in hoistway Before an elevator is put into use, it is required to perform an self-tuning of landing distance in hoistway, in order to study all kinds of data in hoistway, and save these data permanently.
the choice of service layer By handheld operator, lift can be set to stop which floor, and which floor do not park.
character setting for floor symbols This function can be done through handheld operator, character can be set in various floors, such as underground first floor is set by "B"etc.
attendant service The attendant operation feature allows semi-automatic operation with manual control.
independent service This function is designed for meeting customers'special needs. When switched on independent service the elevator will only answer any registered car call deviating from group control, regardless of the hall calls while opening or closing the door by manual control and operating according to customers' registered signals.
Fire emergency return to run When encountered fire, after setting the fire switch to place, elevator immediately eliminate all instructions and calling, operate to the fire basement in the fastest way, then open the door to stop.
Automatic correction floor position signal During system running, revise the location of the data by self learning to location signal of elevator of each terminal switch action point and each layer leveling switch action point
Elevator lock service Run automatically or driver condition, after elevator lock switch is setting, which will eliminate all call to register, only response instructions until no registration in the car. And then return to the basement, automatically open the door and turn off lighting and fan in the car, light open button lights, automatically close door after 10 seconds delay, and then stop running. After elevator lock switch is reset, elevator will start normal operation.
The protection of non open door outside the landing door in order to be safe, outside the landing door, no open the door.
Light Curtain Light red unit for special purpose enhanced the safety of elevator, an infrared curtain can be formed in front of the car door, and a quick response to reopen will be implemented once something entering this area.But light curtain did not work in fire fighting.
overload protection When the load of the car exceeds rated capacity. Overload operations is triggered, this operation opens the door, sounds the buzzer, and illuminations the overload lamp. The overload conditions is removed when the weight of the car fails below the rated load.
anti-nuisance car call protection If there is only one passenger in the car, and an excessive number of car calls is registered, nuisance is detected and all caar calls will be cancelled, requiring registration of a proper number of calls.
reverse running protection Whenever the system inspects a converse movement of an elevator as contradicting to the signaling direction, the elevator will stop all of its operations, and the fault alarm will be sounded, until the problem is fixed or the control panel is rechanged again.
Running time limiter When an elevator operates contiously, if the operating time exceed the stipulatied time(Max 45 seconds), the flat layer's switch no action, then the elevator will stop operation.
Deceleration switch fault protection Under the conditions of deceleration switch failure, elevator stop urgently to prevent header or squat down bottom.
protecting elevators from runnby floors Every elevator is installed with terminal deceleration switch and terminal limit switches on its upper and lower terminal landing, in order to ensure that the elevator will not surpass the distance of travel.
safety loop protection Security system received safety loop failure signal, the elevator will immediately stop operation until the obstacle solved.
overspeed protection When speed beyond control run result in safety and protection.
Flat layer switch fault protection In order to prevent the abnormal situation made by failure flat layer switch, elevator adopts a security protection.
shaft self-learning failure diagnosis The shaft data is the basis of a control system for high speed operation, if no accurate shaft data, the elevator will not be able to run normally, so the shaft self-learing failure diagnosis should be set when shaft self-learing failed to complete.
Door lock fault protection When system detects door lock abnormal, in order to prevent elevator running continuously, this function is usded to make sure the safety of elevator.
the door lock off protection in the operation It is detected the door lock off in the operation, the elevator has to stop operation.
parallel running Two elevators transfer data through CAN serial communication bus to realize and coordinate the function of each landing doors' call in two elevators. so as to improve the operation efficiency of elevator.
NDG When an elevator has NDG function, if the light curtain action or other reasons make door continuously opening without door-shut signal, the door was forced to close with NDG signals.
Waiting for base station opening Elevator is selected in base station to open door for waiting through the parameter
Time floor block function It is thespecified blocked service to specified floor at a specific time. Specific blockade service refers to individually block outside call registration, also individually block the instruction registration, also block instructions and outside call registration, and also not block.
CAN communication interference evaluation Controller tests the quality of CAN communication.
Coder iterference assessmen Controller tests the Coder signal interference.
car testing Provide a revolutionary way of the elevator testing, worker can directly testing the lift, monitor the elevator running status in the car, in order to make the function such as elevator flat layer, comfort more hunmanize.











 

Contact us if you need more details on Elevator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Lift、Elevator Components. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Passenger Elevator